Cold-formed structural pipe and door frames staged on a commercial jobsite

Pipes · Frames · Panels

Peacemaker Structural Pipe Systems for Commercial Builds

Specify load-rated pipe assemblies, architectural door frames, and wall panel systems with published compressive strength, fire resistance rating, and dimensional tolerances—then request a quote without brochure filler.

Grouped structural performance data

Reference values used on Peacemaker submittals for cold-steel pipe, hollow-metal frames, and acoustic wall panels. Confirm project-specific load bearing capacity with the engineering desk before release.

Structural Pipe Systems
Typical wall thickness0.120–0.250 in
Yield strength class36–50 ksi
Dimensional tolerance±0.005 in on OD
Coating optionsMill / galvanized / epoxy primer
Architectural Door Frames
Frame gauge16 / 14 / 12 ga
Fire resistance rating20 / 45 / 90 min paths
Throat sizes4-7/8 to 8-3/4 in
Anchor typesMasonry / stud / existing opening
Wall Panel Systems
STC rating rangeSTC 42–56 assemblies
Panel thickness2–6 in stacked cores
Moisture vapor transmissionDocumented per core type
Service life expectancy25–40 year design paths

Core product families

Four compact lines covering the assemblies most frequently scheduled on Peacemaker commercial packages.

Structural pipe fittings close-up

Structural Pipe Systems

Pipe · Fittings
Hollow metal door frame

Architectural Doors & Frames

Frames · Hardware prep
Acoustic wall panel stack

Wall Panel Systems

STC · Fire-rated
Fastening and joinery kit

Fastening & Joinery

Anchors · Clips

Why estimators shortlist Peacemaker

  • Tested beyond industry standards

    Load, pressure, and weathering trials exceed baseline ASTM and ANSI checkpoints before SKUs release to the catalog.

  • Certified safe and code-aligned

    UL Listed pathways, ANSI/ASHRAE notes where HVAC interfaces apply, and IBC structural code language on submittals.

  • Precision-engineered field fit

    Tolerances held to ±0.005 in on structural components so pipe, frame, and panel interfaces assemble cleanly on site.

  • Data before adjectives

    Spec sheets lead with compressive strength, fire resistance rating, and STC rating—not lifestyle photography.

Credentials that travel with the submittal

ISO

ISO 9001:2015

Quality management covering fabrication, dimensional inspection, and lot traceability across pipe, frame, and panel lines.

UL

UL Listed assemblies

Fire-rated door frame and panel assemblies documented for the hour ratings commonly scheduled on commercial corridors.

IBC

IBC structural code alignment

Load path language and fastening schedules written for structural reviewers who need more than a logo strip.

ANSI

ANSI / ASHRAE interface notes

Where pipe systems meet mechanical rooms, coordination notes reference airflow and vibration isolation interfaces.

Need a pipe schedule or frame takeoff reviewed?

Send opening sizes, load notes, and panel STC targets. Peacemaker returns a shortlist with measurable parameters—not a generic brochure pack.